DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant BL40p G1 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant BL40p G1 Overview
HP ProLiant BL40p Server Blade
42U Rack with HP ProLiant BL40p
System Installed
|
|
1.
|
BL p-Class Interconnects (2) in HP BladeSystem
p-Class server blade enclosure (interconnect switch shown |
2.
|
HP ProLiant BL40p server blades (2) in HP BladeSystem
p-Class server blade enclosure |
3.
|
HP BladeSystem p-Class 3U power enclosure with
hot-plug power supplies (6) |
|
|
What's New
- New HP BladeSystem p-Class 1U Power Enclosure
- The HP BladeSystem Management Suite is delivered
in a convenient to purchase pack which includes a BL p-Class Server
Blade Enclosure with enhanced backplane components, a single copy of
Systems Insight Manager (SIM) and 8 licenses for each of the following
products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP)
and the Vulnerability and Patch Management Pack (VPM).
HP ProLiant BL40p Server Blade includes:
- Intel Xeon MP FC-PGA 3.0GHz\4MB or 2.2GHz\2MB processor
(quad capability)
- ServerWorks GC-LE Chipset
- 512-MB or 1024 MB of 2-way interleaved PC2100 ECC
DDR (2 x 1 Interleaved Memory), expandable to 12 GB
- Advanced Memory Protection with Online Spare
- Five NC7781 PCI-X Gigabit NICs (embedded) with WOL
(Wake On LAN) and Preboot eXecution Environment (PXE)
- One additional 10/100T NIC dedicated to Integrated
Lights-Out (iLO) Management
- Smart Array 5i Plus Controller with battery-backed
write cache (integrated on system board) standard on the 3.0GHz/4M model,
optional on the 2.2GHz/2M model
- Wide Ultra3 SCSI Drive Cage standard supports up
to four 1" hot plug hard drives
- Two PCI-X slots (64b/100MHz capable) for redundant
SAN connectivity
- Integrated Lights-Out (iLO) Management (ASIC on motherboard)
- Plugs vertically into p-Class server enclosure
- Up to 12 HP ProLiant BL40p server blades fit in 42U
rack
|
What's Needed
HP BladeSystem p-Class Server
Blade Enclosure:
- Server blades and interconnects slide into p-Class
server blade enclosures for network connection and power
- Server blade enclosure is 6U high and 10 bays across.
The server blade enclosure bays consist of 2 (outer) interconnect bays
and 8 server bays. One server blade enclosure can hold up to 2 HP ProLiant
BL40p server blades and 2 interconnects
- Types of interconnects available: GbE Interconnect
Switches, GbE2 and CGESM Interconnect Switches with optional Fibre Channel
pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass
through
HP BladeSystem p-Class Power Enclosures:
- Use BL p-Class sizing tool to determine power based
on your configuration https://h30099.www3.hp.com/configurator/powercalcs.asp
- Choose the HP BladeSystem p-Class 3U power enclosure
or the HP BladeSystem p-Class 1U power enclosure
- Choose single-phase or three-phase power
- HP BladeSystem power enclosures with power supplies
are not needed if using facility -48VDC ± 10%, in this case purchase
facility DC option kit
HP BladeSystem p-Class Power Distribution (only required
with the 3U power enclosure):
- Distributes power from the power enclosure to the
server blade enclosures
- Four power distribution choices:
- HP BladeSystem p-Class
scalable bus bar
- HP BladeSystem p-Class mini bus bar
- HP BladeSystem p-Class power bus box
- Dual power input kit
for mini bus bar (required for support of two power enclosures
- NOTE: Power requirements for a HP
BladeSystem p-Class: 200V - 240V AC, 30 amp or facility DC -48V ±
10%.
- HP ProLiant BL40p server blade, p-Class server blade
enclosures, interconnects and power enclosures protected by a limited
three year warranty with optional service uplifts available
- SATA drives have a 1 year warranty
|
|
|
HP ProLiant BL40p Server Blade
|
+
|
|
|
|
HP BladeSystem p-Class Server Blade Enclosure
|
+
|
|
|
|
OR |
|
|
Patch Panel (shown) or Patch Panel 2
|
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or
CGESM Interconnect Switch
(fiber or copper-based)
|
|
HP BladeSystem p-Class Interconnects
|
|
+
|
|
|
|
|
HP BladeSystem p-Class 3U power enclosures and
power supplies
|
OR
|
|
|
|
HP BladeSystem p-Class 1U power enclosures and
power supplies
OR
|
Facility DC
|
+
|
|
|
|
OR |
|
OR |
|
Scalable bus bar
|
HP BladeSystem p-Class power distribution
|
Bus boxes
|
|
Configuration Steps
For a complete configuration of the HP ProLiant BL40p
server blade, do the following:
- Select a HP ProLiant BL40p server blade:
Single Xeon MP 2.2GHz processor, 512-MB RAM (2 x 256MB) ( 345628-B21)
Or
Single Xeon MP 3.0GHz processor, 1-GB RAM (2 X 512M) (344286-B21)
NOTE: Additional options include
processors, memory, and PCI-X HBAs.
PLUS
- Decide how many HP BladeSystem p-Class Server Blade
Enclosures to purchase (each enclosure can hold up to 2 HP ProLiant
BL40p server blades):
HP BladeSystem p-Class server blade enclosure with enhanced backplane
components with 8 Rapid Deployment Pack licenses (281404-B22)
Or
HP BladeSystem p-Class server blade enclosure with enhanced backplane
components with Rapid Deployment Pack trial (243564-B22)
Or
HP BladeSystem p-Class server blade enclosure with enhanced backplane
components and the HP BladeSystem Management Suite which is delivered
in a convenient to purchase pack that includes a single copy of Systems
Insight Manager (SIM) and 8 licenses for each of the following products:
Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the
Vulnerability and Patch Management Pack (VPM).( 380625-B22)
Or
Optional HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit(354100-B21)
PLUS
Select an Interconnect Kit. Each Interconnect Kit contains a pair of
interconnects except the Cisco GESM which contains a single switch per
kit. One pair of interconnects is required with each ProLiant BL p-Class
server blade enclosure:
BL p-Class RJ-45 Patch Panel (with 32 RJ-45 connectors) ( 230766-B21)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class
Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45
10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with
or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module
(378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without
ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel
connectivity when using the CGESM Interconnect Switch)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class
Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45
10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000
T/TX/T SFP modules) (378927-B21), with or without optional ProLiant
BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors)
(321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity
when using the CGESM Interconnect Switch)
Or
BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink
ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) ( 283192-B21), with
or without optional ProLiant BL p-Class Storage Connectivity Kit (with
16 Fibre Channel connectors) (321745-B21) (required for ProLiant BLxxp
xx Fibre Channel connectivity when using the GbE2 Interconnect Switch)
or BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink
ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) ( 283193-B21),
with or without optional ProLiant BL p-Class Storage Connectivity Kit
(with 16 Fibre Channel connectors) (321745-B21) (required for ProLiant
BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect
Switch)
Or
BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink
ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21)
Or
BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and
16 RJ-45 10/100 T/TX downlink ports) (279775-B21) Or
BL p-Class server blade enclosure with enhanced backplane components
with 8 Rapid Deployment Pack licenses (281404-B22)
Or
BL p-Class server blade enclosure with enhanced backplane components
with 8 Rapid Deployment Pack trial (243564-B22)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class
Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45
10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with
or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module
(378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without
ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLxxp xx Fibre Channel
connectivity when using the CGESM Interconnect Switch)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class
Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45
10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000
T/TX/T SFP modules) (378927-B21), with or without optional ProLiant
BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors)
(321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity
when using the GbE2 Interconnect Switch) or BL p-Class C-GbE2 Interconnect
Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000
T/TX/T uplink ports ) ( 283192-B21), with or without optional ProLiant
BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors)
(321745 -B21) (required for ProLiant BLxxp xx Fibre Channel connectivity
when using the CGESM Interconnect Switch)
Or
BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink
ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) ( 283193-B21),
with or without optional ProLiant BL p-Class Storage Connectivity Kit
(with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant
BLxxp xx Fibre Channel connectivity when using the GbE2 Interconnect
Switch)
Or
BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink
ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21)
Or
BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and
16 RJ-45 10/100 T/TX downlink ports) (279775-B21)
- Select a HP ProLiant BL40p server blade:
Single Xeon MP 2.2GHz processor, 512-MB RAM (2 x 256MB) ( 345628-B21)
Or
Single Xeon MP 3.0GHz processor, 1-GB RAM (2 X 512M) (344286-B21)
NOTE: Additional options include
processors, memory, and PCI-X HBAs.
PLUS
- Decide how many HP BladeSystem p-Class Server Blade
Enclosures to purchase (each enclosure can hold up to 2 HP ProLiant
BL40p server blades):
HP BladeSystem p-Class server blade enclosure with enhanced backplane
components and the HP BladeSystem Management Suite which is delivered
in a convenient to purchase pack that includes a single copy of Systems
Insight Manager (SIM) and 8 licenses for each of the following products:
Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the
Vulnerability and Patch Management Pack (VPM).( 380625-B22)
NOTE: The HP ProLiant BL40p server
blade does not currently support (PMP). Future support is planned.
PLUS
- Select a HP BladeSystem p-Class power enclosure
and power supplies based on configuration. Use p-Class sizing tool to
help determine power configuration: https://h30099.www3.hp.com/configurator/powercalcs.asp
NOTE: Power enclosures and supplies
are not needed if using facility DC (-48V ± 10%).
Single phase 3U power enclosure with four hot-plug power supplies (NA/JPN-
239162-001) (Single-phase 3U power enclosure holds a max of four power
supplies; no need to order additional power supplies with this option
kit) (INTL - 239162-421)
Or
Three-phase 3U power enclosure with six hot-plug power supplies (NA/JPN-
230769-001) (INTL - 230769-421) (Three-phase 3U power enclosure holds
a max of six power supplies no need to order additional power supplies
with this option kit)
(Power enclosures and power supplies can also be purchased separately.
See options list below.)
Or
1U power enclosure with six power supplies ( 378284-B21)
Or
1U power enclosure with two power supplies ( 380314-B21) (Additional
power supplies can also be purchased separately. See options list below.)
PLUS
Select power distribution (only required with 3U power enclosures):
Scalable bus bar - Supports up to 5 server blade enclosures*
( 240560-B21)
Or
Mini bus bar - Supports up to 3 server blade enclosures*
(240559-B21)
Or
Power Bus Box - Supports only 1 server blade enclosure*
(240562-B21)
Or
Dual Power Input Kit for Mini Bus Bar - required for support of two
power enclosures. (364565-B21)
Or
HP Modular Distribution Unit 40 Amp (NA/JPN) (P/N 252663-D75)**
Or
HP Modular Distribution Unit 40 Amp (Int'l) (P/N 252663-B34)** Or HP
Modular Distribution Unit 32 Amp (Int'l) (P/N 252663-B33)**
Or
HP Modular Distribution Unit 24 Amp (NA/JPN) (P/N 252663-D74)**
*NOTE: Maximum depends upon power
input.
**NOTE: The Modular Distribution Unit Kits excludes the extension
bars as they are not required with the HP BladeSystem p-class 1U power
enclosure.
|
Standard Features (Server Blade)
BL40p Hard Drives |
Ultra320 SCSI – Universal
Hot Plug Hard Drives |
|
300-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
300-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
146.8-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
146.8-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
72.8-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
72.8-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
36.4-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
36.4-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
NOTE: All U320
Universal Hot Plug Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller to support U320 transfer
rates. |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html
(North America) |
|
HP ProLiant BL40p Server Blade |
Processor
One of the following depending
on Model: |
Xeon MP processor 3.0 GHz/4MB
|
Xeon MP processor 2.2 GHz/2MB |
|
Upgradeability |
Upgradeable to quad processing |
|
Cache Memory |
4-MB Level 3 Cache (on the 3.0GHz
Model) |
2-MB Level 3 Cache (on the 2.2GHz
Models) |
|
Memory Protection |
Advanced Memory Protection with
Online Spare |
|
Memory |
Type
|
2-way interleaved PC2100 ECC
DDR |
(2 X 256 MB) |
Standard
|
512MB
(1 processor model) |
Maximum
|
12,288 MB
|
(2 X 512MB) |
Standard
|
1024MB
(2 processor model) |
Maximum |
12,288 MB |
NOTE:
Memory must be installed in pairs. Advanced Memory Protection with Online
Spare. |
|
Network
Controller |
Six network adapters total:
|
| Five
NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE | | One
10/100T iLO NIC dedicated to management |
|
Manageability |
Integrated Lights-Out (iLO)
Management Advanced (ASIC on the System Board) |
|
Internal Storage |
Hard Drives |
None ship standard |
Maximum Internal
Storage |
SCSI |
1200 GB (internal drive cage)
|
(4 x 300 GB) |
NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. |
|
Expansion Slots |
Two Dedicated PCI-X slots (64b/100MHz
capable) for redundant SAN connectivity |
I/O cable |
I/O cable connectors: |
(2)USB ports, (1) video port,
(1) iLO port and (1) kernel debug port |
(2) I/O cables ship with every
server blade enclosure |
Tested USB devices (keyboard,
mouse, floppy) are listed in options section of this QuickSpecs |
|
Dimensions |
6U high x 7" wide. Fits
within p-Class Server Blade Enclosure. One HP ProLiant BL40p server blade
takes up four (4) server blade bays within a server blade enclosure. Two
HP ProLiant BL40p server blades can fit within one server blade enclosure. |
Standard Features (Server Blade Enclosure and Interconnects)
HP BladeSystem p-Class Server
Blade Enclosure and ProLiant BL p-Class Interconnects |
HP BladeSystem p-Class Server
Blade Enclosure |
6U (10.5-inch), 19-inch wide
Holds up to 2 HP ProLiant BL40p server blades; 8 HP ProLiant BL20p server
blades; or a combination of both.
10 bays per server blade enclosure:
- 8 bays for server blades
- 2 outside bays for interconnect modules (RJ-45 Patch Panels, RJ-45
Patch Panel 2, GbE2 Interconnect Switches, GbE Interconnect Switch or
CGESM Interconnect Switch)
Server blades slide in and connect to the server blade enclosure back
plane for power and data connections
Up to 6 BL p-Class server blade enclosures fit in a 42U rack
Server blade management module attached to the back of each BL p-Class
server blade enclosure to report all server events and provide asset and
inventory information
|
|
HP BladeSystem p-Class Power
Requirements |
Redundant 200V - 240V AC, 30
amp single-phase for NA and International
Redundant 208V 30amp 3-phase 4 wire, NA
Redundant 380 - 415V 20A 3-phase 5 wire, Intl
Redundant -48VDC ± 10% |
|
HP ProLiant BL p-Class Interconnect
Switch Option
(Two switches per kit)
(Every HP BladeSystem p-Class server blade enclosure requires two interconnect
switches OR two RJ-45 patch panels)
|
Provides up to a 32 to 1 server networking cable reduction per server
enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL20p
G2, and HP ProLiant BL40p server blades. Each interconnect switch (two
per enclosure) reduces up to sixteen internal server network (NICs) ports
to six external ports (four on a modular rear mounting interconnect module
and two on the switch front panel). This provides a total of twelve external
ports per server blade enclosure. Only one to all twelve external ports
may be used per server blade enclosure.
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is
for applications that require network adapter consolidation to 1000 Mbps
(Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same
HP ProLiant BL40p G2 Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one
CGESM Interconnect Switch or one CGESM Interconnect Switch populated with
two (2) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules.
Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide
two Interconnect Switches providing any combination of up to twelve (12)
RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per server blade enclosure.
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that
require network adapter consolidation to 1000 Mbps (Gigabit Ethernet)
and BL25p Fibre Channel pass-through.
- The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2
Interconnect Switches and two QuadSX Interconnect Modules that provide
eight (8) LC 1000 SX and two (4) RJ-45 10/100/1000 T/TX/T external ports
per server blade enclosure.
- The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2
Interconnect Switches and two QuadT2 Interconnect Modules that provide
twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade
enclosure.
- The optional ProLiant BL p-Class Storage Connectivity Kit (321745
-B21) is required for BL25p Fibre Channel pass-through when using either
the CGESM, C-GbE2 or F-GbE2 Interconnect Kit.
Also included (per Interconnect Switch):
- One (1) RS-232 DB-9 front panel out-of-band management port
- Redundant crosslink ports connecting the two interconnect switches
- Redundant power inputs and on-board redundant fans
- Hot-plug and hot-remove with configuration retention and no need to
cable/re-cable
- Power ON, management, and per port status and speed LED indicators
- Reset/power momentary push-button switch
- HP ProLiant BL Interconnect Switch Management Utilities and User Documentation
CD
- Fully pre-configured for rapid deployment and immediate operation
- ProLiant BL Interconnect Switch Management System and Utilities:
Full featured web-based and scriptable command line (CLI) interfaces,
password protected multi-level user accounts, Telnet, SNMP, BootP client,
port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible
multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast
storm control, flow control, human readable/writeable configuration file,
TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation
and auto-sensing with full-duplex support, and more.
|
|
HP ProLiant BL p-Class RJ-45
patch panel |
6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure
out as RJ-45 connections
Supports Gigabit Ethernet network controllers. 16 RJ-45 connectors on
the back of each BL p-Class 6U RJ-45 patch panel (32 RJ-45 connections
per server blade enclosure).
|
(Two patch panels per kit)
(Every HP BladeSystem p-Class server blade enclosure requires two interconnect
switches OR two RJ-45 patch panels) |
|
Required
Network Cabling | 10Base-T |
Categories 3, 4 or 5 UTP (100
meters)
EIA/TIA-568 100-ohm STP (100 meters)
|
| 100Base-TX |
Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
| | 1000Base-T | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | | 1000Base-SX | 50/125
µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode
Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km
(220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
Standard Features (Power System and Rack Information)
HP BladeSystem p-Class 3U Power
Enclosure |
3U (5.25-inch), 19-inch wide,
29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase
and three phase models available. HP BladeSystem 3U p-Class power enclosure
provides external, shared hot-plug power. Each three-phase power enclosure
houses up to six hot-plug power supplies each single-phase power enclosures
hold up to four hot-plug power supplies to power the BL p-Class server blades
and interconnects.
Please use the sizing utility to determine the power needed for each configuration.
https://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
Power enclosures and power supplies are not needed if using facility DC
(-48V DC ± 10%). If using facility DC, only Facility DC Power Connection
kit part number (240563-B21) is needed.
|
|
HP BladeSystem p-Class 1U Power
Enclosure |
1U (1.75-inch), 19-inch wide,
29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase
or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power.
Each 1U power enclosure houses up to six hot-plug power supplies to power
up to one server blade enclosure, fully populated with BL p-Class server
blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration
https://www.hp.com/go/bladesystem/powercalculator.
Power enclosures and power supplies are not needed if using facility DC
(-48V DC ± 10%). If using facility DC, only Facility DC Power Connection
kit part number (240563-B21) is needed. |
|
HP BladeSystem p-Class Power
Distribution (only required with 3U power enclosures) |
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power
(from the power enclosures or facility DC power) is distributed from the
power enclosures to the server blade enclosures through a bus bar system.
Hinges attach the HP BladeSystem bus bars to the rails in a rack. The
bus bars swing open from the center to enable easy rear access to the
server blades and network cables. Power is distributed redundantly through
independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on
the maximum number of server blade enclosures planned for the rack:
- HP BladeSystem p-Class scalable bus bar
- HP BladeSystem p-Class mini bus bar
- HP BladeSystem p-Class power bus box
NOTE: To support a full 42U rack server
blades (6 server blade enclosures), two mini bus bars are needed.
|
Required
Power Source | Two
30-amp redundant power feeds per power enclosure | | Connectors |
| NEMA
receptacles (NA/Japan) | | | NA
1-phase | L6-30, 250v, 30A 3-wire |
| | NA
3-phase | L15-30, 250V, 30A,
4-wire | | IEC
309 Pin & Sleeve connectors (International) | | | Intl
1-phase | 250V, 32A, 3- pin (2
pole + ground) | | | Intl
3-phase | 380-415V, 32A, 5--pin
(4 pole + ground) | | Optimized
for power cabling from bottom and network cabling from top |
Standard Features
ProLiant Essentials Foundation Pack Software for the
ProLiant BL Server Blades
|
ProLiant Essentials Rapid
Deployment Pack |
Rapid Deployment Pack
(RDP) is an automated deployment and provisioning solution for all
ProLiant servers. RDP includes the Altiris Deployment Solution and
ProLiant Integration Module featuring ProLiant server pre-configured
events for OS installation, and optimized software drivers, firmware
and management agents. Every RDP CD includes 10-node trial licenses
for evaluation purposes. RDP requires a license for each server deployed
and are available for purchase with blade servers. For more information,
visit https://www.hp.com/servers/rdp. |
HP Systems Insight Manger |
HP Systems Insight Manager
(HP SIM) help maximize system uptime and performance and reduce system
maintenance costs by providing proactive notification of problems
before those problems result in unplanned downtime or reduced productivity.
HP SIM is easy to set up to work with the Insight Management Agents,
integrated Light-Out and Remote Insight Light-Out Edition, and Version
Control Agents to deliver robust fault, configuration, and asset management
as well as remote administration. With HP Systems Insight Manager
customers will also be able to take advantage of role-based security;
the ability to manage ProLiant, Integrity, and HP9000 systems; and
plug-ins for storage, client, printer, and power management as well
as server rapid deployment, performance management, and workload management.
For more details on HP Systems Insight Manager visit https://www.hp.com/go/hpsim. |
|
Management Agents |
The Management Agents
form the foundation for HP's Intelligent Manageability strategy. They
provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, and portables, and send alerts
to HP Systems Insight Manager and other enterprise management applications
in case of subsystem or environmental failures. For additional information
about the Management Agents and other management products from HP,
please visit the management Web site at https://www.hp.com/servers/manage. |
|
Subscriber's Choice |
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription
service that provides software and driver change notifications for
ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis. |
|
ROMPaq, support software,
and
configuration utilities
|
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options, available in the RDP CD, SmartStart or downloadable from
Software and Drivers download pages, linked from the SmartStart website
at https://www.hp.com/go/support |
|
Insight Diagnostics Online
Edition |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP and at
your fingertips, available in SmartStart. |
|
NOTE: For more
information regarding ProLiant Essentials Software, please see the following
URL: https://www.hp.com/servers/proliantessentials
|
|
Optional ProLiant
Essentials Value Packs |
Optional software offerings that selectively extend the functionality
of an Adaptive Infrastructure to address specific business problems and
needs:
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route based
on network conditions.
- Performance Management Pack - a performance management solution that
identifies and explains hardware performance bottlenecks on ProLiant
servers and attached options enabling users to better utilize their
valuable resources
- Virtual Machine Management Pack - provides central management and
control of virtual machines from Microsoft and VMware. Integrated approach
provides the ability to manage both physical and virtual resources from
a single management console.
- Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well operating
system configurations that can be exploited by viruses, worms, and other
blended threats
- Workload Management Pack - provides easier management of complex environments,
improving overall server utilization and enabling Windows® 2000
customers for the first time to confidently deploy multiple applications
on a single multiprocessor ProLiant Server.
|
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. |
|
SmartStart |
SmartStart is a tool that simplifies single server setup, providing a
rapid way to deploy reliable and consistent server configurations. SmartStart
7.00 and later can now deploy the HP ProLiant BL20P G3 and HP ProLiant
BL40P server blades, using the I/O port with an attached USB CD-ROM device.
To obtain a copy of SmartStart for your blade server, redeem the coupon
that is included with your Blade server or order your copy from the SmartStart
web site. For more information, please visit the SmartStart Web site at
https://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 6.20
|
|
Intelligent Manageability |
Integrated Lights-Out Advanced (iLO)
Virtual CD-ROM
Virtual Floppy *
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Automatic Server Recovery-2 (ASR-2)
Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM Based Setup Utility (RBSU)
Advanced Configuration and Power Interface Specification Ready (ACPI)
Server Health Logs
HP Redundant Power Supply Utility
Pre-Failure Warranty (covers processors, as well as hard drives and memory)
HP Interconnect Switch Management System and Utilities (interconnect switch
option)
Integrated Management Log (IML)
Dynamic sector repairing and drive parameter tracking (with Smart Array
controllers)Redundant/adaptive load balancing NIC Support
* Advanced features such as Graphical Remote Console and Virtual Floppy
are included with the BL p-Class server.
|
|
Availability |
Power redundancy: Redundant AC feeds into power enclosures; redundant
DC feeds from power enclosure to server blade enclosures, 1 + 1 redundant
power supplies
Four hot-plug SCSI hard drive bays and integrated RAID (Smart Array 5i
Plus Controller with 64-MB total Memory on the 5i Plus Memory Module)
on every server blade. Battery Backed Write Cache Enabler Module standard
on the 2 processor model and optional on the 1 processor model. Redundant
ROM on each server blade
ECC Memory
Interconnects Switch Availability
- Hot-plug and hot- remove with configuration retention and no need
to cable/re-cable
- Two network connections per server blade bay (four NICs total) routed
to two redundant interconnect switches
- Redundant inter-switch communication with two sets of redundant uplink
ports per each interconnect switch
- Redundant front panel ports per each interconnect switch for diagnostics,
management, and additional uplinks
- Redundant serial ports
- Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning
tree protocol support for loop-free path redundancy
- Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic
port load balancing and failover
- Redundant switch configuration images in memory (GbE2 switch)
- Redundant fans per each interconnect switch
- Redundant 1+1 power to each interconnect switch
- Support for ProLiant network adapter teaming
- Redundant configurable community strings and SNMP trap manager hosts
- Redundant configurable syslog server, DNS server, and default gateways
(GbE2 switch)
|
|
Security |
Power-on password
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface
time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE
802.1Q tagged VLANs, RADIUS user authentication and authorization*, and
IP address restriction
* CGESM and GbE2 Interconnect Switch only.
|
|
Minimum Rack Requirements |
Mounts in HP Telco racks and Third Party racks that meet the following
criteria:
- Compatible with 19-inch Standard EIA rail sets
- EIA rail-to-rail depth is 29 - 30"
- Cabinet depth must be at least 36-inch deep overall (Additional min.
3.5-inch clearance from rear RETMA rail to rear door, inclusive in the
36-inch overall depth)
- Ample room for top and bottom cable egress (approximately 8 square
inches for full rack configuration with patch panel)
- Must be capable of supporting 1600 lb (for full rack configuration)
- Perforated front and rear doors to accommodate front-to-back cooling
- Must have 65% open perforation on server blade enclosure doors to
support airflow requirements
- Optimized for use with the 10000 Series racks
NOTE: If using 7000 Series rack, Rack
Extension Kit and High Air Flow Rack Door options are required.
|
|
Rack Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
- Front and rear doors: If your 42U
server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top
to bottom to permit adequate airflow (equivalent to the required 64
percent open area for ventilation).
- Side: The clearance between the
installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
NOTE: For additional
information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the
Support section at the following URL: https://h18000.www1.hp.com/products/servers/proliant-bl/p-class/40p/documentation.html.
|
|
Factory Express Portfolio for
Servers and Storage |
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000
& EVA5000, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to https://www.hp.com/go/factory-express.
|
|
Service
and Support |
Three-year limited warranty,
including hardware diagnostic support, pre-failure warranty (coverage of
processors, memory and SCSI hard drives.) The warranty is fully supported
by HP Services and a worldwide network of resellers and service providers.
In addition 90-day's getting started software telephone support may be covered
under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services.
NOTE: Sever Blade Limited Warranty includes 3 year Parts, 3 year
Labor, 3-year on-site support.
NOTE: Server Blade Enclosure and Interconnects Limited Warranty includes
3 year Parts, 3 year Labor, 3-year on-site support.
NOTE: SATA drives have a 1 year warranty.
Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available
including:
- Installation and start up
- Education courses
- Extended onsite hardware coverage hours from same business day 13
hours, 5 day to 24 hours, 7 days call window with options including
4-hour response or 6-hour Call To Repair
- Comprehensive range of software technical support for Microsoft,
Linux, ProLiant Essentials and VMWare-based IT solutions helping to
deliver high level of application availability. Response times range
from 30 mins for critical problems to 2 hours.
- System Management, Performance Services and Mission Critical Support
Solution
HP Care Pack services for ProLiant BL p-Class server blades, cover the
server blade and the p-Class blade enclosure that the server blade is
installed in as well as interconnects, power enclosure with power supplies
and power distribution.
NOTE: For more information on
HP Care Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: https://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers
and resellers, please visit us at: https://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty
and technical support is available at:
https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
|
Models
ProLiant
BL40p P3.0-4MB, 1GB (2P)
344286-B21
| Processor(s) |
(2) Xeon MP 3.0 GHz standard
(up to 4 supported) |
Cache Memory |
4-MB Level 3 Cache (per processor) |
Memory |
1024 MB (Standard) of 2-way
interleaved PC2100 ECC DDR (2 X 512 MB) |
Network Controller |
Five NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE
One additional 10/100T NIC dedicated to iLO Management |
Storage Controller |
Smart Array 5i Plus Controller
(integrated on system board) with BBWC |
Hard Drives |
None ship standard |
Internal Storage |
Up to 1200 GB maximum |
Optical Drive |
None |
Form Factor |
6U high x 7" wide. Fits
within p-Class Server Blade Enclosure |
|
ProLiant BL40p P2.2-2MB,
512MB (1P)
345628-B21
|
Processor(s) |
(1) Xeon MP 2.2 GHz standard
(up to 4 supported) |
Cache Memory |
2-MB Level 3 Cache (per processor) |
Memory |
512 MB (Standard) of 2-way interleaved
PC2100 ECC DDR (2 X 256 MB) |
Network Controller |
Five NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE
One additional 10/100T NIC dedicated to iLO Management |
Storage Controller |
Smart Array 5i Plus Controller
(integrated on system board) |
Hard Drives |
None ship standard |
Internal Storage |
Up to 1200 GB maximum |
Optical Drive |
None |
Form Factor |
6U high x 7" wide. Fits
within p-Class Server Blade Enclosure |
Options
HP
ProLiant BL40p server blade Unique Options |
Xeon MP 3.0GHz
4MB Processor Option Kit |
344287-B21 |
Xeon MP 2.2GHz
2MB Processor Option Kit |
345627-B21 |
HP BladeSystem
p-Class Diagnostic Station Upgrade Kit for the HP ProLiant BL40p server
blade |
309329-B21
|
|
ProLiant
Essentials
Value Pack Software |
ProLiant Essentials
Intelligent Networking Pack |
|
ProLiant Essentials
Intelligent Networking Pack, Single Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
|
NOTE:
For additional ProLiant Intelligent Networking Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html |
|
ProLiant Essentials
Performance Management Pack |
|
ProLiant Essentials
Performance Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key, HP Management
CD and documentation.
NOTE: The most recent version of the software can always be downloaded
at https://www.hp.com/products/pmp.
|
306696-B21
|
NOTE:
For additional ProLiant Performance Management Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html
|
|
ProLiant Essentials
Rapid Deployment Pack Windows Edition and Linux Edition Release |
|
Rapid Deployment
Pack, Single-Server License
NOTE: This license allows 1 server
to be deployed and managed via RDP.
|
267196-B21
|
Rapid Deployment
Pack, Single-Server License (Japan)
NOTE: This license allows 1 server
to be deployed and managed via RDP.
|
267196-291
|
NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html
https://h18000.www1.hp.com/products/quickspecs/11713_div/11713_div.html
|
|
ProLiant Essentials
Server Migration Pack |
|
ProLiant Essentials
Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling
1 server migration, with a unique license activation key and documentation.
NOTE: This license allows 1 server to be migrated from a physical
server to a virtual machine. Or this license can be used to migrate a virtual
machine from one virtualization layer i.e. VMware GSX to a different virtualization
layer such as VMware ESX or Microsoft Virtual Server 2005.
|
375345-B21
|
NOTE:
For additional ProLiant Server Migration Pack License Kits please see the
QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12170_div/12170_div.html
|
|
ProLiant Essentials
Workload Management Pack |
|
ProLiant Essentials
Workload Management Pack, Single Server License |
|
NOTE:
For additional ProLiant Workload Management Pack License Kits please see
the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html
|
|
ProLiant Essentials
Workload Management Pack |
|
ProLiant Essentials
Workload Management Pack, Single Server License |
|
NOTE:
For additional ProLiant Workload Management Pack License Kits please see
the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html
|
|
ProLiant Essentials
Virtual Machine Management Pack |
|
ProLiant Essentials
Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
372214-B21
|
NOTE:
For additional ProLiant Virtual Machine Management Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12110_div/12110_div.html |
|
ProLiant Essentials
Vulnerability and Patch Management Pack |
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
371645-B21
|
NOTE:
For additional ProLiant Vulnerability and Patch Management Pack License
Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html
|
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials or the
various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials.
|
|
|
Processor |
Xeon MP 3.0GHz 4MB Processor Option
Kit |
344287-B21 |
Xeon MP 2.2GHz 2MB Processor Option
Kit |
345627-B21 |
|
Memory
(DDR DIMMs) | 512MB of PC2100 ECC
DDR DIMM Memory Kit (2x256MB) |
| 1024MB
of PC2100 ECC DDR DIMM Memory Kit (2x512MB) |
| 2048MB
of PC2100 ECC DDR DIMM Memory Kit (2x1024MB) |
| 4096MB
of PC2100 ECC DDR DIMM Memory Kit (2x2048MB) |
|
|
BL40p Hard Drives |
Ultra320 SCSI – Universal
Hot Plug Hard Drives |
|
300-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
300-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
146.8-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
146.8-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
72.8-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
72.8-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
36.4-GB 15,000 rpm U320 Universal Hot Plug Hard Drive |
|
36.4-GB 10,000 rpm U320 Universal Hot Plug Hard Drive |
|
NOTE: All U320
Universal Hot Plug Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller to support U320 transfer
rates. |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html
(North America) |
|
Storage Controllers |
Battery Backed Write Cache Enabler
Option Kit |
|
Battery Backed Write Cache Enabler
Option Kit (Japan) |
255514-291
|
Smart Array 6402/128 Controller |
|
Smart Array 6404/256 Controller |
|
Smart Array 642 Controller |
|
256MB DDR, Battery-Backed Cache
Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed
Cache Module upgrade kit supports the Smart Array 6400 series controller
only.
|
|
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the
Smart Array 641 Controller and Smart Array 642 Controller.
|
|
NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information:
https://h18000.www1.hp.com/products/quickspecs/11063_div/11063_div.html
(Smart Array 5i Plus)
https://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html
(Smart Array 6400 Series)
https://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.html
(Smart Array 642) |
|
|
Tape Libraries
|
HP StorageWorks MSL6000 Tape Library |
|
Ultrium 960 technology
|
|
MSL6030,
1 drive, 30 slots, Ultrium 960
|
|
MSL6030,
2 drive, 30 slots, Ultrium 960
|
|
MSL6030,
1 drive, 30 slots, Ultrium 960, with embedded FC router
|
|
MSL6030,
2 drive, 30 slots, Ultrium 960, with embedded FC router
|
|
MSL6060,
2 drive, 60 slots, Ultrium 960
|
AD610A
|
MSL6060,
2 drive, 60 slots, Ultrium 960, with embedded FC router |
AD611A
|
SDLT 600 technology
|
|
MSL6026, 1 drive, 26 slots, SDLT
600
|
AD582A
|
MSL6026, 2 drive, 26 slots, SDLT
600
|
AD583A
|
MSL6026,
1 drive, 26 slots, SDLT 600, with embedded FC router
|
AD584A
|
MSL6026, 2 drive, 26 slots, SDLT
600, with embedded FC router
|
AD585A
|
MSL6052, 2 drive, 52 slots, SDLT
600
|
AD587A
|
MSL6052, 2 drive, 52 slots, SDLT
600, with embedded FC router |
AD588A
|
Ultrium 460 technology
|
|
MSL6030, 1 drive, 30 slots, Ultrium
460
|
|
MSL6030, 2 drive, 30 slots, Ultrium
460
|
|
MSL6030, 1 drive, 30 slots, Ultrium
460, with embedded FC router
|
|
MSL6030, 2 drive, 30 slots, Ultrium
460, with embedded FC router
|
|
MSL6060, 2 drive, 60 slot Ultrium
460 |
AD603A
|
MSL6060, 2 drive, 60 slot Ultrium
460, with embedded FC router |
AD604A
|
NOTE: Please reference
the MSL6000 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs. |
|
HP StorageWorks MSL5026S2 Tape
Library
|
|
MSL5026S2,
1 DRV, SDLT320, RM Library
|
|
MSL5026S2, 2 DRV, SDLT320, RM
Library
|
|
MSL5026S2, 1 DRV, SDLT320, Fibre
Channel, RM Library |
|
MSL5026S2, 2 DRV, SDLT320, Fibre
Channel, RM Library |
|
NOTE:
Please reference the MSL5026S2 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs. |
|
HP StorageWorks MSL5052S2 Tape
Library
|
|
MSL5052S2, 2 DRV, SDLT320, RM
Library
|
293474-B21 |
MSL5052S2, 2 DRV, SDLT320, Fibre
Channel, RM Library |
293474-B24 |
NOTE: Please reference
the MSL5052S2 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
HP StorageWorks MSL5060 Tape
Library |
|
MSL5060, 2 drive, 60 slots, Ultrium
230, RM with embedded FC router |
301899-B22 |
MSL5060, 2 drive, 60 slots, Ultrium
230, TT |
301899-B23 |
NOTE: Please reference
the MSL5060 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
HP StorageWorks ESL E-Series
Tape Libraries |
|
ESL Extended 712e Tape Library,
0 drive, 712 LTO slots |
AA934B |
ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots
|
AA935B |
ESL Extended 322e Tape Library,
0 drive, 322 LTO slots
|
AA939B |
ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots
|
AA940B |
ESL E-Series Ultrium 960 drive
kit |
AD595A |
ESL E Ultrium 460 drive kit
|
AA937A |
ESL E Ultrium 460-FC drive kit |
AA941A |
ESL E SDLT 320 drive kit |
AA936A |
ESL E e2400-FC Interface Controller |
AA928A |
NOTE: Please reference
the ESL E-Series Tape Libraries QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
Magneto-Optical Jukeboxes
|
HP StorageWorks 9.1 GB Mid-range Optical
Jukeboxes
|
|
300mx, 2 drive, 32 slot jukebox |
C1150M |
600mx, 4 drive, 64 slot jukebox |
C1160M |
700mx, 2 drive, 76 slot jukebox |
C1170M |
NOTE: Please reference the
Magneto-Optical Jukebox data sheets at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
HP StorageWorks 9.1 GB High-end Optical
Jukeboxes |
|
1200mx, 4 drive, up to 128 slots |
C1104M |
1200mx, 6 drive, up to 128 slots |
C1105M |
2200mx, 4 drive, up to 238 slots |
C1111M |
2200mx, 6 drive, up to 238 slots |
C1107M |
2200mx, 10 drive, up to 238 slots |
C1110M |
|
HP BladeSystem p-Class
Server Blade Enclosures |
HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components and the HP BladeSystem
Management Suite
NOTE: Includes a HP BladeSystem p-Class
Server Blade Enclosure with enhanced backplane components, a single copy
of Systems Insight Manager (SIM) and 8 licenses for each of the following
products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP)
and the Vulnerability and Patch Management Pack (VPM).
NOTE: The HP ProLiant BL40p server blade does not currently support
(PMP). Future support is planned.
|
|
HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components (ProLiant Essentials
Rapid Deployment Pack Trial) |
243564-B22
|
HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components (8 ProLiant Essentials
Rapid Deployment Licenses) |
281404-B22
|
HP BladeSystem p-Class Server
Blade Enclosure Upgrade Kit (option)
NOTE: Server Blade Enclosure Upgrade
Kit (354100-B21) contains enhanced backplane components and enables a field
upgrade of a blade enclosure to support BL p-class blades and provide a
single, physical iLO port for the enclosure. |
354100-B21
|
|
HP BladeSystem p-Class
Interconnects |
ProLiant BL p-Class RJ-45 Patch
Panel 2 with Fibre Channel pass-through (pair) (required for ProLiant BL20p
G2 Fibre Channel connectivity when using the RJ-45 Patch Panel 2)
NOTE: Only one interconnect kit required
per server blade enclosure. |
306465-B21
|
ProLiant BL p-Class RJ-45 Patch
Panel (pair)
NOTE: Only one interconnect kit required
per server blade enclosure. |
|
ProLiant BL p-Class C-GbE2 Interconnect
Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect
Modules)
NOTE: Only one interconnect kit required
per server blade enclosure.
|
|
ProLiant BL p-Class F-GbE2 Interconnect
Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect
Modules)
NOTE: Only one interconnect kit required
per server blade enclosure.
|
|
Cisco
Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit only
NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378926-B21
|
Cisco Gigabit Ethernet Switch
Module for HP BladeSystem p-Class Interconnect Kit Base Unit (with two RJ-45
10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules.
NOTE: Two CGESM interconnect kits
required per server blade enclosure. |
378927-B21
|
Cisco RJ-45 10/100/1000 T/TX/T
SFP Module |
378928-B21
|
Cisco Fiber SX SFP Module |
378929-B21
|
ProLiant BL p-Class Storage Connectivity
Kit (with pair of OctalFC Interconnect Modules and two Fibre Channel signal
conditioning cards)
NOTE: Required for BL20P G3 Fibre
Channel signal pass through when using the CGESM or GbE2 Interconnect Switch.
NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect
Kit.
NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect
Kit. |
321745-B21
|
ProLiant BL p-Class C-GbE Interconnect
Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)
NOTE: Only one interconnect kit required
per server blade enclosure.
NOTE: The GbE Interconnect Switch supports server NIC speeds to 100
Mbps. It is recommended that the GbE2 Interconnect Switch or a patch panel
option be used if server NIC speeds to 1000 Mbps are required.
NOTE: To meet applicable radio frequency (RF) emission limits, the
sidewall panels on the ends of any individual rack or a series of coupled
racks and the front and rear doors must be installed in any racks containing
more than one ProLiant BL p-Class GbE Interconnect Kit.
|
249655-B21
|
ProLiant BL p-Class F-GbE Interconnect
Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect
Modules)
NOTE: Only one interconnect kit required
per server blade enclosure.
NOTE: The GbE Interconnect Switch supports server NIC speeds to 100
Mbps. It is recommended that the GbE2 Interconnect Switch or a patch panel
option be used if server NIC speeds to 1000 Mbps are required.
NOTE: To meet applicable radio frequency (RF) emission limits, the
sidewall panels on the ends of any individual rack or a series of coupled
racks and the front and rear doors must be installed in any racks containing
more than one ProLiant BL p-Class GbE Interconnect Kit. |
279775-B21
|
ProLiant BL p-Class Storage Connectivity
Kit (with two Fibre Channel signal conditioning cards and two OctalFC Interconnect
Modules) (required for ProLiant BL20p G2 Fibre Channel connectivity when
using the GbE2 Interconnect Switch) |
321745-B21
|
|
HP BladeSystem p-Class
Power options |
NOTE: Use p-Class
sizing tool to help determine power configuration:
https://www.hp.com/products/configurator.
|
|
Single Phase 3U Power Enclosure
with 4 power supplies (NA/JPN)
(Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no
need to order additional power supplies with this option kit)
|
|
Single Phase 3U Power Enclosure
with 4 power supplies (Int'l)
(Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no
need to order additional power supplies with this option kit)
|
239162-421
|
3 Phase 3U Power Enclosure with
6 power supplies (NA/JPN)
(3 Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need
to order additional power supplies with this option kit)
|
|
3 Phase 3U Power Enclosure with
6 power supplies (Int'l)
(3 Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need
to order additional power supplies with this option kit)
|
230769-421
|
Single 3U Phase Power Enclosure
(empty) (NA/JPN)
(Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001
|
Single 3U Phase Power Enclosure
(empty) (Int'l)
(Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-421
|
3 3U Phase Power Enclosure (empty)
(NA/JPN)
(Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001
|
3 3U Phase Power Enclosure (empty)
(Int'l)
(Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-421
|
Single 3UPower Supply |
|
Facility DC Power Connection |
240563-B21
|
1U Power Enclosure with six power
supplies
|
|
1U Power Enclosure with two power
supplies
|
|
Single 1U Power Supply |
|
|
Power Distribution
(only required with 3U power enclosures) |
HP BladeSystem p-Class Scalable
Bus Bar |
|
HP BladeSystem p-Class Mini Bus
Bar |
240559-B21
|
HP BladeSystem p-Class Bus Power
Box |
240562-B21
|
HP Modular Distribution Unit 40
Amp (NA/JPN)*
|
252663-D75
|
HP Modular Distribution Unit 40
Amp (Int'l)*
|
252663-B34
|
HP Modular Distribution Unit 32
Amp (Int'l)*
|
252663-B33
|
HP Modular Distribution Unit 24
Amp (NA/JPN)* |
|
*NOTE: The Modular
Distribution Unit Kits excludes the extension bars as they are not required
with the HP BladeSystem p-class 1U power enclosure.
|
|
HP BladeSystem Power Extension
Kit
NOTE: When upgrading a standard
server blade enclosure(s) to enhanced server blade enclosure(s) and using
mini bus bars, this option kit allows a second, redundant 3U power enclosure
to be installed above the server blade enclosure(s) rather than below. The
option kit consists of two extension cable assemblies - one for each side
(A and B) of the power infrastructure. |
381686-B21
|
|
Diagnostic Options |
HP BladeSystem p-Class Diagnostic
Station
NOTE: The Diagnostic Station allows
access to the ProLiant p-Class server blades and the BL p-Class interconnect
switches outside of the server enclosure. The option provides power and
a data interface so that "offline" upgrade and diagnostic functions
may be performed.
|
|
HP BladeSystem p-Class Diagnostic
Station Upgrade Kit for the HP ProLiant BL40p server blade
|
309329-B21
|
|
SAN Switches |
McDATA 4Gb SAN Switch
|
A8001A
|
HP StorageWorks SANtegrity Enhanced
License
|
T4263A
|
Brocade 4GB SAN Switch, Base
|
A7533A
|
Brocade 4GB SAN Switch, full fabric
|
A7534A
|
Brocade 4GB SAN Switch, power
pack
|
A7535A
|
|
Other Options |
HP BladeSystem BL p-Class Server
Enclosure Shipping Bracket Option Kit
NOTE: Used to secure one server blade
enclosure in a rack when moving. |
293121-B21
|
HP BladeSystem BL p-Class Power
Enclosure Shipping Bracket Option Kit
NOTE: Used to secure one power enclosure
in a rack when moving. |
365044-B21
|
|
External Storage -
Rack |
HP StorageWorks Modular Smart
Array 20
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies.
|
|
HP StorageWorks Modular Smart
Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies. Includes
Smart Array 6402/128 Controller.
|
|
NOTE: The Modular
Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1" Hot Plug
Hard Drives. |
|
HP StorageWorks Modular Smart
Array 30 SB
NOTE: Rack-mountable 14 drive enclosure
with single bus, redundant power supplies
|
|
HP StorageWorks Modular Smart
Array 30 DB
NOTE: Rack-mountable 14 drive enclosure
with dual bus, redundant power supplies
|
|
NOTE: The Modular
Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 1"
Hot Plug Hard Drives. |
|
Redundant Power Supply 499W |
|
Ultra320 Dual Bus I/O Module for
MSA30 |
|
Ultra320 Single Bus I/O Module
for MSA30 |
|
|
HP StorageWorks Modular
Smart Array 1500 cs |
Modular Smart Array 1500 Controller
Shelf |
|
NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at:
https://www.hp.com/go/MSA1500cs
|
|
|
Controllers and Host Bus Adapters
|
FCA2404DC 2Gb PCI-X-to-FC HBA
for W2K and Windows Server 2003 |
|
FCA2404 2Gb PCI-X HBA for W2K
and Windows Server 2003 |
|
FCA2214 2Gb PCI-X FC HBA for Windows
and Linux |
|
FCA2214DC 2 Gb Dual Channel PCI-X
FC HBA for Windows |
|
|
USB Options |
USB 1.44-MB External Diskette
Drive (Carbonite) |
DC141B |
USB 2-Button Optical Mouse (Carbonite) |
DC172B |
USB 2-Button Scroll Mouse (carbonite) |
DD441B
|
|
256MB Hp Drive Key II (USB 2.0) |
PH657A |
|
HP Rack 5000 Series |
HP5642 Rack-Unassembled |
|
|
Rack Options for
Rack 5000 Series
|
Stabilizer Kit for 5642 Rack (Graphite
Carbon)
NOTE; The stabilizer kit is used
to prevent rack from tipping over.
|
374493-B21
|
Baying Kit for 5642 Rack (Graphite
Carbon)
NOTE: The baying kit is used to join
two or more HP 5642 rack.
|
374499-B21
|
|
HP Rack
10000 Series
(Graphite Metallic)
|
Rack, HP Infrastructure 42U (HV)
|
|
Rack, HP Infrastructure 42U (LV) |
379006-001
|
HP S10614 (14U) Rack Cabinet -
Shock Pallet |
|
HP Rack 10842 (42U) - Pallet
NOTE: Server Blade Enclosures must
be field integrated into the 10842 racks. Factory integration of Server
Blade Enclosures into the 10842 is not supported.
|
|
HP Rack 10842 (42U) - Shock Pallet
NOTE: Server Blade Enclosures must
be field integrated into the 10842 racks. Factory integration of Server
Blade Enclosures into the 10842 is not supported.
|
|
HP Rack 10842 (42U, 800mm wide) - Pallet
|
245160-B21
|
HP Rack 10842 (42U, 800mm wide) - Shock Pallet
|
245160-B23
|
HP Rack 10647 (47U) - Pallet
|
245161-B21
|
HP Rack 10647 (47U) - Crated
|
245161-B22
|
HP Rack 10642 (42U) - Pallet
|
245161-B23
|
HP Rack 10642 (42U) - Shock Pallet
|
245162-B21
|
HP Rack 10642 (42U) - Crated
|
245162-B22
|
HP Rack 10636 (36U) - Pallet
|
245162-B23
|
HP Rack 10636 (36U) - Shock Pallet
|
245163-B21
|
HP Rack 10636 (36U) - Crated
|
245163-B22
|
HP Rack 10622 (22U) - Pallet
|
245163-B23
|
NOTE: -B21 (pallet)
used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom
systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Not all HP equipment is qualified to be shipped in the Rack
10000 series. |
|
|
Rack Options for HP
Rack 10000 Series
|
HP Rack Light Kit (Neon) |
|
HP Rack Plinth Kit (Carbon) |
|
800mm Wide Stabilizer Kit (Graphite)
|
255488-B21
|
NOTE: Supported
by the Rack 10842 cabinet only. |
|
600mm Stabilizer Kit – Graphite
|
246107-B21
|
Baying Kit for Rack 10000 series (Carbon)
|
248929-B21
|
42U Side Panel – Graphite Metallic
|
246099-B21
|
110V Fan Kit (Graphite)
|
257413-B21
|
NOTE: Roof Mount
Includes power cord with IEC320-C13 to Nema 5-15P. |
|
220V Fan Kit (Graphite)
|
257414-B21
|
NOTE: Roof Mount
Includes power cord with IEC320-C13 to Nema 6-15P. |
|
36U Side Panel – Graphite Metallic
|
246102-B21
|
47U Side Panel – Graphite Metallic
|
255486-B21
|
9000/10000 Series Offset Baying Kit (42U)
|
248931-B21
|
NOTE: This kit
can be used to connect 9000 and 10000 series racks of the same U height
together. Kit contents include hardware for connecting racks and a panel
to cover the 100mm gap at the rear of the two racks. |
|
NOTE:
For additional information regarding
Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
Ballast Option Kit |
|
9000/10000 Series Offset Baying
Kit (42U) |
248931-B21
|
NOTE: This kit
can be used to connect 9000 and 10000 series racks of the same U height
together. Kit contents include hardware for connecting racks and a panel
to cover the 100mm gap at the rear of the two racks. |
|
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html
|
|
100 kg Sliding Shelf
|
234672-B21
|
Monitor/Utility Shelf - Graphite
|
253449-B21
|
Depth Adjustable Fixed Rail
|
332558-B21
|
Cable Management D-Rings Kit
|
168233-B21
|
TFT5600 Rack Keyboard Monitor
|
221546-xx1
|
TFT7210R Rack Mounted 17"
Monitor |
|
TFT5600 Rack Keyboard Monitor |
221546-xx1
|
1U Rack Keyboard & Drawer
(Carbon) |
257054-xx1
|
Country Code Key (for TFT5600
RKM Rack Keyboard Monitor
(P/N 221546-xx1)and 1U Rack Keyboard & Drawer (Carbon)(P/N 257054-xx1)) |
|
XX = 00 |
US |
XX = 09 |
Norway |
XX = 03 |
UK |
XX = 10 |
Sweden/Finland |
XX = 04 |
Germany |
XX = 11 |
Switzerland |
XX = 05 |
France |
XX = 13 |
Portugal |
XX = 06 |
Italy |
XX = 18 |
Belgium |
XX = 07 |
Spain |
XX = 29 |
Japan |
XX = 08 |
Denmark |
XX = B3 |
International |
|
|
NOTE: For a complete
list of Monitors please view the following URL:
https://h18004.www1.hp.com/products/monitors/ |
|
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
|
HP KVM Switch Options |
IP Console Switch Box (KVM/IP),
1 x 1 x 16 |
|
IP Console Switch Box (KVM/IP),
3 x 1 x 16 |
|
Serial Interface adapter - 1 Pack
with power supply
|
|
Interface adapter - USB 1.0 (single
pack) |
|
CAT5e Cable 3', 4 pack |
|
CAT5e Cable 6', 8 pack |
|
CAT5e Cable 12', 8 pack |
|
CAT5e Cable 20', 4 pack |
|
CAT5e Cable 40', 1 pack |
|
|
Rack Options for
Telco Racks |
Bus Bar Telco Rail Option Kit |
245249-B21
|
Enclosure Telco Rail Option Kit |
|
|
Service and Support
Offerings (HP Care Pack Services) |
NOTE: The
HP Care Pack service part numbers below for ProLiant BL p-Class server
blades, cover the server blade and all HP branded hardware options
qualified for the server, purchased at the same time or afterwards,
internal to the server. |
|
Hardware Services On-site
Service |
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic
|
UD187E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
UD188E
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UD189E
|
The HP Care Pack service
part numbers below for HP BladeSystem p-Class server blade enclosure
covers the enclosure including patch panels, HP supported Ethernet
interconnects, power enclosure with power supplies and power distribution. |
|
Hardware Services On-site
Service |
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
HC031E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
HC032E
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
HC033E
|
NOTE: The
HP Care Pack service part numbers below covers the HP BladeSystem
Brocade and McData SAN Switches. |
|
Hardware Services On-site
Service |
|
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage,
3 Years, Electronic
|
UC007E
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
UC008E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
UC009E
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
UC023E
|
|
Installation & Start-up
Services |
|
HP Installation & Startup
Service for HP BladeSystem Infrastructure - provides for an integrated
hardware and software implementation that includes remote service
planning, onsite deployment of hardware and software, installation
verification testing and customer orientation. Hardware deployment
covers the installation of a single BladeSystem enclosure that include
server blades (up to 16), Ethernet network interconnect, and power
options. Software deployment covers the installation and configuration
of HP Systems Insight Manager (SIM), HP Rapid Deployment Pack (RDP),
and deploy up to two operating system editions of either Windows or
Linux, using scripted operating system installation software. |
UC905E
|
ProLiant BL p-Class Blade
Server Hardware Installation, Electronic |
UA219E
|
HP BladeSystem p-Class Enclosure
and Server Blade Hardware Installation, Electronic |
U4971E
|
Provides for the Installation
and Start-up of Rapid Deployment Pack on a Customer supplied server
designated as a Deployment Server. Includes the deployment of a single
server. This new server will be deployed using either one of the pre-configured
scripts or an image. In addition, the service will provide for the
capture and storage of the configuration of the newly deployed server
and orientation on product usage. To be delivered during standard
office ours, standard office days. Electronic. |
U5683E
|
Provides for the Installation
and Start-up of Rapid Deployment Pack Implementation of Rapid Deployment
Pack (Basic) (Electronic) |
UA042E
|
HP ProLiant Essentials Vulnerability
and Patch Management Pack Installation and Startup Service. Service
coverage: onsite installation of the Vulnerability and Patch Management
(VPM) software on a customer designated server, configuration of the
VPM software to acquire security patches, enabling the VPM software
to scan up to five (5) systems, applying the security patches to the
designated servers, generating a report from VPM that shows the vulnerability
assessment results, and providing customer with an orientation to
the software. |
UC929E
|
Provides for the Installation
and Start-up of System Insight Manager (Electronic) |
UA041E
|
Provides for the Installation
and Start-up of System Insight Manager (Electronic) |
UA040E
|
NOTE: For
more information, customer/resellers can contact https://www.hp.com/hps/carepack/services/ |
|
Software Operating Environment
Care Packs |
|
Microsoft Software Operating
Environment Software Telephone 9x5 - 3 incident (Electronic) |
U8169E
|
Red Hat Software Operating
Environment Software Telephone 9x5 - 10 incident (Electronic) |
U3402E
|
SUSE Software Operating
Environment Software Telephone 9x5 - 3 incident (Electronic) |
U9615E
|
ProLiant Essentials Operating
Environment, - 5 Day, 8x5,1 year, 3 incident (Electronic) |
U8222E
|
|
Memory
HP ProLiant BL40p Server Blade (2P Model)
|
Standard Memory
1024-MB of 2-way interleaved PC2100 ECC DDR installed
(2 x 512-MB SDRAM DIMM)
Standard Memory Plus Optional Memory
Up to 9216-MB of 2-way interleaved PC2100 ECC DDR memory
is available with the installation of optional DDR DIMM memory expansion
kits.
Standard Memory Replaced with Optional Memory
Up to 12288-MB of 2-way interleaved PC2100 ECC DDR memory
is available with the removal of standard memory and the installation
of optional DDR DIMM memory expansion kits.
|
BL40p G1 Memory
|
Slot
|
|
1
|
2
|
3
|
4
|
5
|
6
|
Standard
|
1,024MB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
Optional
|
9,216MB
|
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum
|
12,288 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
|
Following are memory options available from HP:
|
|
- 2512MB of PC2100 ECC DDR DIMM Memory Kit (2x256MB)
|
300678-B21
|
- 1024MB of PC2100 ECC DDR DIMM Memory Kit (2x512MB)
|
300679-B21
|
- 2048MB of PC2100 ECC DDR DIMM Memory Kit (2x1024MB)
|
300680-B21
|
- 4096MB of PC2100 ECC DDR DIMM Memory Kit (2x2048MB)
|
300682-B21
|
|
HP ProLiant BL40p Server Blade (1P Model)
|
Standard Memory
512MB of 2-way interleaved PC2100 ECC DDR installed
(2 x 256-MB SDRAM DIMM)
Standard Memory Plus Optional Memory
Up to 8704-MB of 2-way interleaved PC2100 ECC DDR memory
is available with the installation of optional DDR DIMM memory expansion
kits.
Standard Memory Replaced with Optional Memory
Up to 12288-MB of 2-way interleaved PC2100 ECC DDR memory
is available with the removal of standard memory and the installation
of optional DDR DIMM memory expansion kits.
|
BL40p G1 Memory
|
Slot
|
|
1
|
2
|
3
|
4
|
5
|
6
|
Standard
|
512MB
|
256 MB
|
256 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
Optional
|
4,608MB
|
256 MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum
|
12,288MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
|
Following are memory options available from HP:
|
|
- 512MB of PC2100 ECC DDR DIMM Memory Kit (2x256MB)
|
300678-B21
|
- 1024MB of PC2100 ECC DDR DIMM Memory Kit (2x512MB)
|
300679-B21
|
- 2048MB of PC2100 ECC DDR DIMM Memory Kit (2x1024MB)
|
300680-B21
|
- 4096MB of PC2100 ECC DDR DIMM Memory Kit (2x2048MB)
|
300682-B21
|
Quickspecs
HP BladeSystem p-Class Server Blade Enclosure
|
Dimensions |
Height |
10.5 in (26.67 cm) |
|
Width |
17.60 in (44.70 cm) |
|
Depth |
28.86 in (73.30 cm) |
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC Nominal -48
VDC |
|
Rated input current |
62.5 A at -48 VDC |
|
Rated input Power |
3000 W |
Individual server
blade bay ratings |
Rated input voltage |
-43 VDC to -53 VDC Nominal -48
VDC |
Rated input current |
6.25 A at -48 VDC |
|
Rated input Power |
300 W |
Temperature range |
Operating |
50° to 95° F (10°
to 35° C) |
|
Non-Operating |
-22° to 140° F (-30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-Operating |
5% to 95% |
Wet bulb temperature |
Operating |
82.4° F (28° C) |
|
Non-Operating |
101.7° F (38.7° C) |
NOTE: Operating
temperature has an altitude derating of 34° F (1° C) per 1,000 ft
(304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048
m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144
m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on
a maximum temperature of 113° F (45° C). Altitude maximum for storage
is 70 KPa. |
|
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane
components
|
Dimensions |
Height |
10.5 in (26.67 cm) |
|
Width |
17.60 in (44.70 cm) |
|
Depth |
28.86 in (73.30 cm) |
Input Specifications |
Rated input voltage |
-43 VDC to -53 VDC Nominal -48
VDC |
|
Rated input current |
125 A at -48 VDC |
|
Rated input Power |
6000 W |
Individual server
blade bay ratings |
Rated input voltage |
-43 VDC to -53 VDC Nominal -48
VDC |
Rated input current |
14.6 A at -48 VDC |
|
Rated input Power |
700 W |
Temperature range |
Operating |
50° to 95° F (10°
to 35° C) |
|
Non-Operating |
-22° to 140° F (-30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-Operating |
5% to 95% |
Wet bulb temperature |
Operating |
82.4° F (28° C) |
|
Non-Operating |
101.7° F (38.7° C) |
NOTE:
Operating temperature has an altitude derating of 34° F (1°
C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is
10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity
of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa. |
|
Operating and Performance Specifications for HP ProLiant BL40p Server
Blade
| Dimensions | Height | 1.69
in (4.29 cm) | | Width | 10.29
in (26.14 cm) | | Depth | 28.00
in (71.12 cm) | Weight
(maximum) | 18.0 lb (8.17 kg) | |
Temperature range | Operating | 50°
to 95° F (10° to 35° C) | | Non-operating | |
| Shipping | -40°
to 140° F (-40° to 60° C) | | Storage | -4°
to 140° F (-20° to 60° C) | Relative
humidity (non-condensing) | Operating | 10%
to 90% | Non-operating | |
| Shipping | 10%
to 90% | | Storage | 10%
to 95% | Maximum wet
bulb temperature | 82° F
(28° C) | | NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per
1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048
m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. |
|
Operating and Performance
Specifications for RJ-45 Patch Panel 2 with Fibre Channel pass through |
Dimensions |
Height |
10.405 in (26.43 cm) |
|
Width |
1.535 in (3.899 cm) |
|
Depth |
27.697 in (70.35 cm) |
Capability |
IEEE 802.2, 802.3,
802.3u |
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps |
|
10 Base-T (full-duplex) |
20 Mbps |
|
100 Base-TX (half-duplex) |
100 Mbps |
|
100 Base-TX (full-duplex) |
200 Mbps |
|
1000 Base-TX (full-duplex) |
1000 Mbps |
Connector |
Network |
RJ-45 in the back |
|
Fibre Channel SAN |
Pluggable SFP optical slot in
the front |
Cable Support |
10 Base-TX |
Categories 3, 4, or 5 UTP (2 or
4 pair); up to 328 ft (100 m) |
|
|
100 Base-TX |
Category 5 UTP (2 pair); up to
328 ft (100 m) |
|
|
1000 Base-TX |
Category 5E (4 pair); up to 328
ft (100 m) |
|
Power requirements |
200 mA at + 5V DC;
500 mA at -48V |
|
Temperature range |
Operating |
50° to 95° F (10°
to 35° C) |
|
|
Non-operating |
-22° to 140° F (-30°
to 60° C) |
|
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
|
Non-operating |
5% to 95% |
|
Wet bulb temperature |
Operating |
82.4° F (28° C) |
|
|
Non-operating |
101.7° F (38.7° C) |
|
NOTE:
Operating temperature has an altitude derating of 34° F (1°
C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is
10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity
of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa. |
|
Operating and Performance Specifications for RJ-45 Patch Panel | Dimensions | Height | 10.405
in (26.43 cm) | | Width | 1.535
in (3.899 cm) | | Depth | 27.697
in (70.35 cm) | Capability | IEEE
802.2, 802.3, 802.3u | Network
Transfer Rate | 10 Base-T (half-duplex) | 10
Mbps | | 10
Base-T (full-duplex) | 20 Mbps |
| 100
Base-TX (half-duplex) | 100 Mbps |
| 100
Base-TX (full-duplex) | 200 Mbps |
| 1000
Base-TX (full-duplex) | 1000 Mbps |
Connector | RJ-45 | |
Cable Support | 10
Base-TX | Categories 3, 4, or 5
UTP (2 or 4 pair); up to 328 ft (100 m) | | 100
Base-TX | Category 5 UTP (2 pair);
up to 328 ft (100 m) | | 1000
Base-TX | Category 5E (4 pair);
up to 328 ft (100 m) | Power
requirements | 200
mA at + 5V DC; 500 mA at -48V | Temperature
range | Operating | 50°
to 95° F (10° to 35° C) | | Non-operating | -22°
to 140° F (-30° to 60° C) | Relative
humidity (non-condensing) | Operating | 20%
to 80% | Non-operating | 5%
to 95% | Wet bulb
temperature | Operating | 82.4°
F (28° C) | | Non-operating | 101.7°
F (38.7° C) | NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per
1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048
m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. |
|
Operating and
Performance
Specifications for ProLiant BL p-Class GbE Interconnect Switch
|
Dimensions
|
Height |
10.405 in (26.43 cm) |
Width |
1.535 in (3.899 cm) |
Depth |
27.697 in (70.35 cm) |
Weight |
11.5 lb/5.2 kg per
interconnect switch |
Performance |
9.6 Gbps external
port bandwidth per server blade enclosure (full duplex) |
Forwarding rate 0.15
million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte
packets) |
Non-blocking, full-wire
speed for all connections |
Auto-MDI/MDIX, auto-negotiation
and auto-sensing with full-duplex support |
Forwarding Mode |
Store and forward |
MAC Addresses |
8,191 per interconnect
switch; MAC address based filtering and MAC address packet priority configuring |
Forwarding table age time |
Maximum age: 1 to
1,000,000 seconds; default: 300 seconds |
Memory |
32MB Main, 6MB flash
and 16MB packet buffer per interconnect switch |
Compliance |
IEEE 802.3, 802.3u,
802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac, 802.3ad (Static),
and 802.1Q |
SNMP v1 (RFC 1157)
and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 |
MIB-II (RFC 1213),
Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC
1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP
Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps
(RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps |
IGMP v1 (RFC 1112),
IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC
783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and Modem, |
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps |
10 Base-T (full-duplex) |
20 Mbps |
100 Base-TX (half-duplex) |
100 Mbps |
100 Base-TX (full-duplex) |
200 Mbps |
1000 Base-TX (half and full-duplex) |
2000 Mbps |
1000 Base-SX (full-duplex) |
2000 Mbps |
Connector |
12 RJ-45, 2 DB-9
(C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
EMI |
FCC Class A |
|
ICES-003 Class A |
|
AS/NZS 3548 Class
A |
|
VCCI Class A |
Safety |
UL/CUL Listed Accessory |
|
CE |
Power Requirements |
-48VDC: 1050 mA,
50 W maximum (per interconnect switch) |
Temperature Range |
Operating |
50° to 95° F (10°
to 35° C) |
Non-operating |
-22° to 140° F (30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-operating |
5% to 95% |
Wet Bulb Temperature |
Operating |
82.4° F (28° C) |
Non-operating |
101.7° F (38.7° C) |
NOTE:
Operating temperature has an altitude derating of 34° F (1°
C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is
10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000
ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based
on a maximum temperature of 113° F (45° C). Altitude maximum for
storage is 70 KPa. |
|
Operating and Performance
Specifications for GbE2 Interconnect Switch |
Dimensions
|
Height |
10.405 in (26.43 cm) |
Width |
1.535 in (3.899 cm) |
Depth |
27.697 in (70.35 cm) |
Weight |
12.0 lb/5.4 kg per
interconnect switch |
Performance |
24 Gbps External port
bandwidth per server blade enclosure (full duplex) |
Forwarding rate 1.5
million pps per gigabit port (64-byte packets) |
Auto-MDI/MDIX, auto-negotiation
and auto-sensing with full-duplex support |
Forwarding Mode |
Store and forward |
MAC Addresses |
2,048 per interconnect
switch |
Forwarding table age time |
Maximum age: 1 to
65535 seconds; default: 300 seconds |
Memory |
128MB Main, 32MB flash
and 2MB packet buffer per interconnect switch |
Compliance |
IEEE 802.3, 802.3u,
802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.1s, 802.3ac, 802.3ad
(Static), and 802.1Q |
SNMP v1 (RFC 1157),
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863),
Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037),
RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215),
Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise
Switch MIBs and Environmental Traps |
RADIUS (RFC 2138),
Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC
1119), BOOTP client (RFC 2132), and XModem |
Network Transfer Rate |
10 Base-T (half-duplex) |
10 Mbps |
10 Base-T (full-duplex) |
20 Mbps |
100 Base-TX (half-duplex) |
100 Mbps |
100 Base-TX (full-duplex) |
200 Mbps |
1000 Base-TX (half and full-duplex) |
2000 Mbps |
1000 Base-SX (full-duplex) |
2000 Mbps |
Connector |
12 RJ-45, 2 DB-9
(C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2DB-9 (F-GbE2 Interconnect Kit) |
EMI |
FCC Class A |
ICES-003 Class A |
AS/NZS 3548 Class
A |
VCCI Class A |
Safety |
UL/CUL Listed Accessory |
CE |
Power Requirements |
-48VDC: 2040 mA,
98 W maximum (per interconnect switch without Storage Connectivity Kit) |
-48VDC: 2355 mA, 113
W maximum (per interconnect switch with Storage Connectivity Kit) |
Temperature Range |
Operating |
50° to 95° F (10°
to 35° C) |
Non-operating |
-22° to 140° F (30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-operating |
5% to 95% |
Wet Bulb Temperature |
Operating |
82.4° F (28° C) |
Non-operating |
101.7° F (38.7° C) |
NOTE:
Operating temperature has an altitude derating of 34° F/1° C per
1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048
m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144
m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on
a maximum temperature of 113° F/45° C. Altitude maximum for storage
is 70 KPa. |
|
Operating and Performance
Specifications for GbE Interconnect Switch |
Dimensions |
Height |
10.41 in (26.43 cm) |
|
Width |
1.54 in (3.9 cm) |
|
Depth |
27.7 in (70.35 cm) |
Weight |
11.5 lb/5.2 kg per
interconnect switch |
Performance |
9.6 Gbps external
port bandwidth per server blade enclosure (full duplex) |
|
Forwarding rate 0.15
million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte
packets) |
|
Non-blocking, full-wire
speed for all connections |
|
Auto-MDI/MDIX, auto-negotiation
and auto-sensing with full-duplex support |
Forwarding Mode |
Store and forward |
MAC Addresses |
8,191 per interconnect
switch; MAC address based filtering and MAC address packet priority configuring |
Forwarding table age time |
Maximum age: 1 to
1,000,000 seconds; default: 300 seconds |
BL40p G1 Memory |
32MB Main, 6MB flash
and 16MB packet buffer per interconnect switch |
Compliance |
IEEE 802.3, 802.3u,
802.3ab, 802.3z, 802.1D, 802.1p, 802.3ac, 802.3ad (Static), 802.1Q, and
802.3x |
|
SNMP v1 (RFC 1157)
and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 |
|
MIB-II (RFC 1213),
Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC
1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP
Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps
(RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps |
|
IGMP v1 (RFC 1112),
IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC
783), BOOTO client, (RFC 2132), DHCP client, (RFC 2131) and ZModem |
Network transfer rate |
10 Base-T (half-duplex) |
10 Mbps |
|
10 Base-T (full-duplex) |
20 Mbps |
|
100 Base-TX (half-duplex) |
100 Mbps |
|
100 Base-TX (full-duplex) |
200 Mbps |
|
1000 Base-TX (half and full-duplex) |
2000 Mbps |
|
1000 Base-SX (full-duplex) |
2000 Mbps |
Connector |
12 RJ-45, 2 DB-9 (C-GbE
Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
EMI |
FCC Class A |
|
ICES-003 Class A |
|
AS/NZS 3548 Class
A |
|
VCCI Class A |
Safety |
UL/CUL Listed Accessory |
|
CE |
Power Requirements |
48V: 1050 mA, 50 W
maximum (per interconnect switch) |
Temperature Range |
Operating |
50° to 95° F (10°
to 35° C) |
|
Non-operating |
-22° to 140° F (-30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-operating |
5% to 95% |
Wet bulb temperature |
Operating |
82.4° F (28° C) |
|
Non-operating |
101.7° F (38.7° C) |
NOTE:
Operating temperature has an altitude derating of 34° F (1°
C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is
10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity
of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa. |
|
Operating and
Performance
Specifications for CGESM
Interconnect Switch
|
Dimensions |
Height |
10.405 in (26.43 cm) |
|
Width |
1.6 in (4.06 cm) |
|
Depth |
28 in (71.12 cm) |
Weight |
11.5 lb/5.2 kg per
interconnect switch |
Performance |
28 Gbps Maximum Forwarding
Bandwidth. 38.7mpps Maximum Forwarding Rate (64 Byte Packets) |
|
9018Bytes Jumbo Frames
MTU |
|
Non-blocking architecture.
Wire Speed Performance on all ports |
|
Auto-MDI/MDIX, auto-negotiation
and auto-sensing with full-duplex support |
Forwarding Mode |
Store and forward |
MAC Addresses |
8000 MAC/physical
address Table Size |
BL40p G1 Memory |
128MB DRAM Memory.
16MB Flash Memory |
Compliance |
IEEE 802.1s, IEEE
802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T,
100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization,
IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX
specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X
specification |
|
RMON I and II standards,
SNMPv1, SNMPv2c, and SNMPv3 |
|
(RFC1493) , CISCO-CDP-MIB,
CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB,
CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB,
CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB,
CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-MIB,
CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB,
CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for
VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-MIB,
OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-SYS-MIB, OLD-CISCO-TCP-MIB,
OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the,
CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB,
SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB,
UDP-MIB |
|
1000BASE-T ports,
1000BASE-X (SFP), 1000BASE-SX |
Network transfer rate |
10 Base-T (half-duplex) |
10 Mbps |
|
10 Base-T (full-duplex) |
20 Mbps |
|
100 Base-TX (half-duplex) |
100 Mbps |
|
100 Base-TX (full-duplex) |
200 Mbps |
|
1000 Base-TX (half and full-duplex) |
2000 Mbps |
|
1000 Base-SX (full-duplex) |
2000 Mbps |
Connector |
4 SFP, 2 RJ-45 10/100/1000
T/TX/T, 1 DB-9 |
EMI |
FCC Part 15 Class
A |
|
EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24)
CNS 13438 Class A MIC
CD
MIC |
|
AS/NZS 3548 Class
A CE |
|
VCCI Class A |
Safety |
UL to UL 60950, Third
Edition
C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition
TUV/GS to EN 60950:2000
CB to IEC 60950 with all country deviations
NOM to NOM-019-SCFI |
|
CE Marking |
Power Requirements |
-48VDC: 1050 mA, 125
W maximum (per interconnect switch) |
Temperature Range |
Operating |
50° to 95° F (10°
to 35° C) |
|
Non-operating |
-22° to 140° F (-30°
to 60° C) |
Relative humidity
(non-condensing) |
Operating |
20% to 80% |
Non-operating |
5% to 95% |
Wet bulb temperature |
Operating |
82.4° F (28° C) |
|
Non-operating |
101.7° F (38.7° C) |
NOTE:
Operating temperature has an altitude derating of 34° F (1°
C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is
10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000
ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based
on a maximum temperature of 113° F (45° C). Altitude maximum for
storage is 70 KPa. |
|
Operating and Performance Specifications for 3U Power Enclosures (North
America/Japan)
| | |
Single-Phase Model |
Three-Phase Model | Dimensions | Height | 5.25
in (13.34 cm) | 5.25 in (13.34 cm) |
| Width | 27.15
in (68.96 cm) | 27.15 in (68.96
cm) | | Depth | 17.60
in (44.7 cm) | 17.60 in (44.7 cm) |
Weights | No
hot-plug power supplies | 47.5 lb
(21.55 kg) | 47.5 lb (21.55 kg) |
| All
hot-plug power supplies | 99.5 lb
(45.13 kg) | 125.5 lb (56.93 kg) |
Input requirements | Rated
input voltage | 200 VAC to 240 VAC | 200
VAC to 240 VAC line to line | | Rated
input frequency | 50 Hz to 60 Hz | 50
Hz to 60 Hz | | Rated
input current per side | 24A | 24A
per phase | | Rated
input power per side | 5760 W | 9976
W | | Power
cord | 1 NEMA L6-30P per side | 1
NEMA L15-30 per side | Output
voltage specifications | Rated
output voltage | -48.8 VDC to 54
VDC | -48.8 VDC to 54 VDC |
Rated output current | 99A | 170A |
| Rated
output power | 4298 W | 8310
W | | Nominal
power | 4158 W at 208 VAC | 7752
W at 208 VAC | Ambient
temperature range (See NOTE) | Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | Relative
humidity, non-condensing (See NOTE) | Operating | 20%
to 80% | 20% to 80% |
Non-operating | 5%
to 95% | 5% to 95% |
Wet bulb temperature | Operating | 82.4°
F (28° C) | 82.4° F (28°
C) | | Non-operating | 101.7°
F (38.7° C) | 101.7° F (38.7°
C) | NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per
1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048
m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. |
|
Operating and Performance Specifications for 3U Power Enclosures (International)
| | |
Single-Phase Model |
Three-Phase Model | Dimensions | Height | 5.25
in (13.34 cm) | 5.25 in (13.34 cm) |
| Width | 27.15
in (68.96 cm) | 27.15 in (68.96
cm) | | Depth | 17.60
in (44.7 cm) | 17.60 in (44.7 cm) |
Weights | No
hot-plug power supplies | 47.5 lb
(21.55 kg) | 47.5 lb (21.55 kg) |
| All
hot-plug power supplies | 99.5 lb
(45.13 kg) | 125.5 lb (56.93 kg) |
Input requirements | Rated
input voltage | 200 VAC to 240 VAC | 200
VAC to 240 VAC line to line | | Rated
input frequency | 50 Hz to 60 Hz | 50
Hz to 60 Hz | | Rated
input current per side | 24A | 24A
per phase | | Rated
input power per side | 5760 W | 10,552
W | | Power
cord | 1 IEC 309 3-pin, 32A per
side | 1 IEC 309 5-pin, 32A per
side | Output
voltage specifications | Rated
output voltage | -48.8 VDC to 54
VDC | -48.8 VDC to 54 VDC |
Rated output current | 99A | 180A |
| Rated
output power | 4798 W | 8790
W | | Nominal
power | 4598 W at 208 VAC | 8790
W at 208 VAC | Ambient
temperature range (See NOTE) | Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | Relative
humidity, non-condensing (See NOTE) | Operating | 20%
to 80% | 20% to 80% |
Non-operating | 5%
to 95% | 5% to 95% |
Wet bulb temperature | Operating | 82.4°
F (28° C) | 82.4° F (28°
C) | | Non-operating | 101.7°
F (38.7° C) | 101.7° F (38.7°
C) | NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per
1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048
m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. |
|
Operating and Performance
Specifications for Power Distribution Devices |
|
Power Bus Box |
Mini Bus Bar
|
Scalable Bus Bar
|
Power enclosures or facility
DC feeds supported (3U each) |
1
|
1
|
2
|
Server blade enclosures supported
(6U each) |
1
|
3
|
5
|
Total rack height of supported
enclosures |
9U
|
21U
|
36U
|
Dimensions |
|
|
|
Height |
5.1 in (12.95 cm) |
19.45 in (49.40 cm) |
48.57 in (123.37 cm) |
Width |
3.6 in (9.14 cm) each |
19.74 in (50.14 cm) |
19.74 in (50.14 cm) |
Depth |
3.25 in (8.26 cm) |
2.2 in (5.59 cm) |
2.2 in (5.59 cm) |
Weight |
3.62 lb (1.64 kg) |
13.2 lb (5.9 kg) |
26 lb (11.79 kg) |
Rated operating voltage |
-43.2 VDC to -54 VDC |
-43.2 VDC to -54 VDC |
-43.2 VDC to -54 VDC |
Max total power supported |
3000 W
|
9000 W
|
15,000 W
|
Total max input current at minimum
voltage |
69.44 A at -43.2VDC |
208.32 A at -43.2 VDC |
347.2 A at -43.2 VDC
(equivalent of 175A per feed) |
Total max input current at nominal
voltage |
62.5 A at -48VDC |
187.5 A at -48 VDC |
312.5 A at -48 VDC
(equivalent of 175A per feed) |
Max current per power feed |
70A
|
210A
|
210A
|
Max local ambient temperature |
149° F (65° C)
|
149° F (65° C)
|
149° F (65° C)
|
NOTE:
All systems support redundant A & B feeds. Scalable bus bar supports
dual A and dual B feeds. |
|
Operating and Performance Specifications for Facility DC | Voltage | Nominal
input voltage | -48 VDC |
| Operating
voltage range | -48VDC ±
10% or -43.2 VDC to -52.8 VDC | | Max
Input voltage slew rate | 0.5V/uS |
| Redundant
feed voltages* (A & B) | *A
and B feeds must differ by no more than 5VDC during steady state operation |
| Ripple/Noise | 480
mV PARD** | | Overshoot | Must
remain within regulation limits on all feeds during startup or shutdown |
| Voltage
transients | Must not exceed -60
VDC | Current | Max
steady state input current | 62.5A
per server blade enclosure installed at -48VDC | | Max
steady state current per feed/total |
|
|
Power bus boxes | 70
A/70A | |
Mini bus bars | 210
A/210A | |
Scalable bus bars | 210
A/350A or equivalent of 175A per feed* | In-rush
current | Must support up to 2X
the maximum operating current per server blade enclosure (125 A) for up to 1.0
mS | Input over-current | Customer
provided fusing for facility DC feeds that protects the system from catastrophic
over-current within 20 uS. Fuse should sustain all in-rush and operating currents. |
Max Input Current Slew Rate | 1A/uS |
Max Rated Power | 3000W
per server blade enclosure | | Connections
and Cables | HP provided facility
DC cable connection kit: - The facility DC connection kit supports the
connection of up to four -48VDC, RETURN pairs and ground.
The power
cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105°
C, terminated with bus mating connectors at one end and unterminated at the other
end. The cable length provided enables the customer to route to a fuse panel within
or adjacent to the rack. | | NOTE:
*All systems support redundant A and B feeds. Scalable bus bars support dual A
and dual B feeds. ** Periodic and random noise (PARD). Maximum allowable peak-to-peak
ripple and noise (as measured at the load on any output channel). The ripple and
noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic)
is used for this measurement. Each output is by-passed to return by a 10uF tantalum
capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic
capacitor, at the point of load. The load cable is 12 feet of twisted wire capable
of carrying the current. The printed wiring board assembly is installed in its
enclosure for this measurement, or the measurement leads are properly shielded
with Earth grounds applied to the insert. |
|
|